Honda generator wont start - Honda GXV530 in my ride-on mower won't start, it has no spark on either cylinder. ... Honda EB 3500 generator. Checked oil, good. Pulled rope several times to get oil moving. Turned on the key and it fired up, ran …

 
Generator will not start Troubleshooting (check air filter on generator) Next on the list, inspecting the air filter on the generator. The air filter can be easily accessed by unscrewing the wing nut on top of the air filter box. Here is a break down of the air cleaner assembly, taken from the Honda Generator EG1400X, EG2200x owners manual.. Anchor gmc maryland

never had an issue on a working honda generator not starting. at least on good gasoline. for cold winter temps run 5-30 or 0-30 depending on how cold you are for start up. drain back is a issue if super cold like -5 or colder.. also the air breather warmer kit is a must! if you are on lp or ng in the below zero! click here for the eu2200i page ...Generator combustion is slow due to lean fuel-to-air ratios. Mixing air and fuel in the combustion chamber cannot keep up with the combustion process when combustion is slow. The generator backfires when the exhaust valve is closed due to the valve overlap.In "Chainsaw Guy", Taryl goes over how to fix this electrical issue that's causing your Honda EU6500is generator to pull super hard and also not have any spa...A generator won't start when it isn't getting sufficient fuel, air, and spark. This may be due to a plugged air filter, wrong choke setting, faulty on/off switch, empty fuel tank, plugged fuel filter, clogged fuel line, dirty carburetor, bad spark plug, bad spark arrestor, low engine oil, or faulty fuel cap. Check the battery, starter ...All Honda engines model numbers start with the letter "G," such as "G100", "GX610", or "GXV160." For some engines, you will also need to locate the serial number, which is stamped into the side of the engine. Generators: All Honda generators have a model name with a prefix that starts with "E" such as EB500, EU1000i, or EG5000. The model name ...3. Power Draw. One of the most common reasons a generator won’t start is if there is too much draw from the generator. The electrical equipment that draws power from the machine sucks up all the energy that should be going into starting the engine.A generator starts and then dies due to an empty fuel tank, plugged fuel filter, dirty carburetor, clogged fuel line, bad gas cap, dirty spark plug, faulty ignition coil, low engine oil level, or old gas. Wait for the engine to cool and remove the spark plug wire before performing any repairs. Follow the safety precautions found in your ...I have a honda generator it will start on full choke went you take off the choke choke it revs up then dies the plug is cover in oil ... 22,376 satisfied customers. Generac modelgenerator won't start. Oil level good, new. Generac model(###) ###-####generator won't start. Oil level good, new spark plug, drained old gas and added fresh gas. ...Many of our videos are comedic & satirical & not intended to cultivate antisocial or unlawful behavior. Thank you for supporting our Channel through the belo...Gotta love Hondas. But not this time. Would not start. Nada. Stored carb dry, tank empty. Gas is a tad old (Feb '21) but still works fine in saws etc. There seems to be gas sucked in, plug looked wet after repeated attempts. And starting fluid did not help, either through carb or directly in plug hole.Generator won't stay running? This video provides information on how to troubleshoot a generator and the most likely defective parts associated with this pro...Jan 19, 2022 · You need to know that if you just acquired a new Honda eu3000 generator, you will have to hook up the battery. It does come with a battery, but it is disconn... The purpose of this valve is to automatically shut off the flow of propane if the engine stops for some reason. You have to override this shutoff until the engine is up to speed. An electric cutoff may be operated from an oil pressure switch. A vacuum cutoff will have a line to the intake manifold. Keith.Inverter Generator Only Runs With Starting Fluid | Step By Step DIY RepairIf your generator won't start and only run on starting fluid you more than likely h...The Generator Is Low on Fuel. One of the most common reasons a generator won't start is because there is no or low fuel in the fuel tank. Check the fuel tank. If the levels are low, fill it with fresh gasoline. It's also essential to make sure you're not trying to start your generator with old fuel. Any fuel that is more than two months ...Honda generator eu3000 Hi Can anyone help me. I have a Honda eu3000. It is one of there top of the line units. It was under water for 2 days. It is all dried out now. Motor is stuck. I know the Honda motors are bullet proof. What is the best way to free it up. I was told to take the plug out and squirt marvel mystery oil in. And let it sit.If your generator will not stay running, this fix may just be what you were looking for.Measure the spark plug gap between the two electrodes (one curved, one straight) by a gauge. Check the owner's manual for the recommended electrode gap. In many generators, it is around 0.030 inches. To adjust, bend the curved electrode slightly and gently and measure again with the gauge.You can attempt to repair the hole. 4. Faulty Shut-Off Valve. Check the fuel shut-off valve on your Honda generator. It may be the spot your generator is leaking. Shut-off valves are prone to leaking and must be replaced when you find a leak. The fuel shut-off valve may have a sediment bowl and seal.Among the reasons why your Honda EU2200i generator will start include, low oil levels in the tank, the generator may be out of gas, the battery is dead, the oil sensor is faulty, or the fuel valve is clogged. Also, it could be because you need to replace the spark plugs or the air filter is faulty. Let us discuss this further.This has been a great little generator so I was frustrated when it wouldn't stay running when I started it this winter. It would start easily with one pull ...Images: 2. Yamaha ef2000is Generator - Won't Start. I forgot, left a small amount of fuel in it for an extended time. Now it won't start. I removed the air filter and used quick engine start (sprayed at location in second photo) and it then starts briefly but it won't keep running. I removed the component in the first photo and nothing ...A Honda generator won’t stay running when it is overloaded; is low on engine oil; has a plugged spark arrestor, or isn’t getting sufficient air, fuel, and spark. This may be due to a plugged air filter, plugged fuel filter, clogged fuel line, dirty carburetor, dirty spark plug, insufficient oil level, or trying to power more items than the ...If the engine still won't start, take the generator to your authorized servicing Honda power equipment dealer. Page 22: Auto Choke And Throttle Control System The total amount of power available for each generator model is: EM4000SX 5,000 watts for up to 10 seconds EM5000SX 7,000 watts for up to 10 seconds EM6500SX 7,000 watts for up to 10 ...Hi, Honda Generator. Model EM5000SXA. Frame No. EM5000S-1008277. Engine No. GC05-1050746. The choke had been sticky and reluctant to release despite being lubed when it was serviced last year. I took it apart and made sure all the parts moved freely. The auto-choke vacuum diaphragm looked to be in good shape.kcarney. 1 post · Joined 2012. #19 · May 7, 2012. honda gx 160 wont start. i bypassed the low oil alert and made sure there was fresh gas to. there is gas flowing to the carb. checked the spark plug and still no spark. the only thing i have not checked is the ignition coil any ideas. Like.The Generator Is Low on Fuel. One of the most common reasons a generator won't start is because there is no or low fuel in the fuel tank. Check the fuel tank. If the levels are low, fill it with fresh gasoline. It's also essential to make sure you're not trying to start your generator with old fuel. Any fuel that is more than two months ...According to the specifications page on Honda, the Honda CRV has a towing capacity of 1500 pounds. For a fuel-efficient SUV, the towing capacity of the CRV is in range with its com...If the recoil starter assembly is defective, the engine won't start. Remove the starter assembly and inspect it to determine if it is working properly. When you pull the starter rope, tabs extending from the pulley and cam should grab the hub on the engine, causing the engine to turn. When you release the rope, the tabs should retract and the ...Find out what's wrong on a Honda GX engine that doesn't start. I show how to test the fuel system, compression, ignition coil, low oil sensors and kill switc...Honda generators are renowned for their reliability, durability, and exceptional performance. Whether you need a generator for outdoor activities, emergency power backup, or constr...1. Hold all three buttons ('A', 'Start', and 'Stop') down at the same time for about three seconds until the light blinks orange. 2. Lift up and repeat a second time until the light blinks orange again. 3. Lift up and repeat a third time until the light turns green. Once green, it is reset and ready to pair.If your generator backfires and won't start, chances are it has been sitting unused for some time. In this case, you might need to replace older fluids, broken fuel lines, or even faulty spark plugs. Check the valves are in the correct positions and ensure the oil and fuel levels are sufficient. This article will explore the most common ...Reassemble the generator. 19. Add fuel and start the engine. Check for fuel leaks. 20. Test the generator by performing the load bank test (see Tool Ordering Information on page 6). Maximum Output: 120V, 1.0 kVA, 8.3 Amps Rated Output: 120V, 0.9 kVA, 7.5 Amps 5 x 16 mm WASHER-SCREW (4) MUFFLER PROTECTOR 6 x 20 mm SCREW-WASHER (2) FUEL CAP 10 mm ...Generators sit for long periods and often need carburetor maintenance. This video will show how easy it is to clean your carburetor and get your generator or...Solutions to Predator 9500 Generator Problems. Now that we have identified the common problems with Predator's 9500 generators, let's discuss the solutions: 1. The Engine Won't Start. Charge or replace the battery. Clean or replace the air filter. Refill the fuel tank. Replace the spark plug. 2.Onan propane generator won't start. Onan Marquis 6500 Propane generator. We had quite a bit of trouble with it last year, involving several rounds of repairs. ... Airbags won't inflate: lmcgill: Fleetwood Owner's Forum: 2: 03-26-2012 07:01 PM: First start after winter: ninos: Caterpillar Engine Forum: 7: 03-22-2012 10:48 AM:A bit of a pain, but was wort it. My Yamaha 2000 has to come inside to start when its cold inside! At least the Honda tries! When the weather is cold,approaching freezing and just below, my generator is hard to start. Well really it starts quickly but shuts down after a few seconds for a low oil warning. The oil is not low.If your generator still won't start, check the spark plug. Remove the spark plug and inspect it for any obvious damage. If the porcelain part is damaged, the spark plug won't work. Carbon buildup is another common sparkplug problem. If the spark plug is black and sooty, use a small piece of sandpaper to clean the terminals.Generator won't run gas furnace. I have just gotten a small portable inverter generator (3500/4000) watts. The generator is the type that provides floating neutral power. The generator seems to work fine. It will power a portable electric heater, dehumidifier, lighting etc. When I tested it with my Westinghouse natural gas furnace, I ran into a ...The Generator Is Low on Fuel. One of the most common reasons a generator won't start is because there is no or low fuel in the fuel tank. Check the fuel tank. If the levels are low, fill it with fresh gasoline. It's also essential to make sure you're not trying to start your generator with old fuel. Any fuel that is more than two months ...Nov 25, 2011 / Honda generator won't start. Thread Starter #10 . OP . whistlepig Elite Member. Joined Jan 1, 2009 Messages 4,327 Location Preble County, Ohio Tractor Kubota B7800 with FEL. wdchyd said: Whistlepig,Weighing only 29 pounds, the EU1000 is incredibly lightweight and portable. Thanks to our exclusive Eco Throttle System, the EU1000i offers great fuel efficiency. It runs 3.0 to 6.8 hours on a single tank, depending on the load. Honda's inverter technology means stable, clean power in a smaller, lighter package.To start a generator that has been sitting, first, check that all the components are working. Then drain any old gas, and replace it with fresh gasoline. Also, check the spark plugs and replace them to keep your generator running at optimum levels. Don’t forget to clean the carburetor and check the air filter too.When I try and start my eu7000 generator it just clicks and won't start I charged the battery and it has 12.6 volts, I tried to pull start it but it won't even try to start. ... I also have a Honda 6500 is generator which I converted to Tri-Fuel about 6 months ago using a kit from Central Maine Diesel.2). Faulty Ignition Coil. When you start the engine, the ignition coil sends the voltage to the spark plug. A faulty ignition coil can prevent the spark plugs from generating a spark. Test the spark plug first. If it works, turn your attention to the ignition coil. 3). Ignition Module Problem.As a result, the Honda generator won’t run without a choke. ... The choke should be on while starting the generator as while turning on the engine is cold. Once the engine is warm after running for a while, you should turn off the choke. If there is any issue with the fuel or airflow, the generator may need the choke to be turned on while ...The purpose of this valve is to automatically shut off the flow of propane if the engine stops for some reason. You have to override this shutoff until the engine is up to speed. An electric cutoff may be operated from an oil pressure switch. A vacuum cutoff will have a line to the intake manifold. Keith.To start the engine by operating the starter motor. The recoil starter is used to start the engine if the generator is not equipped with a 12-volt battery to operate the starter motor, or if the battery does not contain adequate charge to operate the starter motor. 07/11/07 10:21:48 31Z21600_011Aug 29, 2019 ... HONDA Generator will start and die on a prime. When we prime carb with a little fuel or starting fluid it starts on prime but dies when ...In other words, it almost catches. I've never had difficulty starting the generator prior to this point. I had back surgery a few months ago and am wondering if my strength is not enough to get things going. Also, I have not had the generator maintained professionally (or by me). It's been about 1-1/2 years since the generator has been run.To start a generator that has been sitting, first, check that all the components are working. Then drain any old gas, and replace it with fresh gasoline. Also, check the spark plugs and replace them to keep your generator running at optimum levels. Don’t forget to clean the carburetor and check the air filter too.Here’s what I’ve found from my experience. If your generator starts but won’t keep running, here are two likely issues to check: make sure that it’s not overloaded. check for fuel or air delivery obstructions. A clogged air filter, vapor lock, or dirty carburetor often cause this issue.This video covers 5 common reasons that a generator might be hard to pull start. Video on how to fix a recoil start assembly: https://youtu.be/sG6JuWCbiw8Th...Aug 29, 2019 ... HONDA Generator will start and die on a prime. When we prime carb with a little fuel or starting fluid it starts on prime but dies when ...1). Defective Voltage Regulator. The regulator plays an important role in the generator's ability to charge the battery. If the voltage regulator is damaged, it will prevent the battery from getting the charge it needs, causing the component to die. You will find that the battery drains at a much faster rate.Mar 27, 2023 · Honda EB3000C has a dead battery: even though most Honda generators last for around ten years, the battery doesn’t necessarily last as long. If you own an RV, you likely use your generator often and wear out the battery. Honda EB3000C has insufficient fuel: If you don’t have enough fuel in your Hyundai EB3000C generator, it won’t turn on ... To start viewing messages, select the forum that you want to visit from the selection below. Page 1 of 3 1 2 3 Last. Jump to page: Results 1 to 25 of 55 Honda Generator Won't Stay Running. Thread Tools. ... Honda Generator Won't Stay Running Check the fuel pickup line. Goes from inside the tank to the carb.Engine is a Honda GX390, Recoil Start, Oil Alert equipped. Attached to a pressure washer. Engine will start cold, first pull and run beautifully until shut off via the switch. After that, it will not restart until cool again. - Oil level fine - Fresh gasoline - Clean air filter - Good spark - Valve clearance to spec.Feb 15, 2023 ... How To Easily Fix Your Honda EB3800X Generator Won't Start Or Stay Running Carburetor Replacement · Comments28.The problem with my Generac Generator was that you had to disconnect the battery from the starter to charge it and then reconnect it to use the electric star...Honda EX4500 generator won't start. Will run on starting. Honda EX4500 generator won't start. Will run on starting fluid. Has fuel in float bowl. ...Hardly there are generators that can be started with a remote or switch or key. When the pull cord is operating normally, it is expected to come out when pulled outwards and retract back when released. The pull cord retracts because of a recoil spring wounded around the pulley on its lower side. Now, sometimes, the generator won't pull start ...If that is so, then your generator will refuse to start. You can prevent this by emptying the fuel tank and carburetor. To check if this is the reason, check if the fuel is reaching the carburetor by inspecting the position of the fuel valve. If the valve is closed, then the fuel won't flow to the carburetor. You can open the valve.4. Use Fresh Fuel. One of the common causes your Generac generator won't start because the gasoline is old. Gasoline tends to degrade over time. If the fuel looks cloudy or looks like there's been some separation, you should consider replacing it with fresh fuel. Siphon the gas and fill the tank with fresh gas.Honda generators equipped with electric start contain low-maintenance batteries manufactured by Yuasa. These batteries require very little maintenance, but they do require periodic charging. To get the longest service life from your battery, keep it fully charged at all times or recharge it each time you consume about a quarter of its capacity. ...The Black Max Generator leaks gas. The carburetor bowl has a gasket underneath it to prevent any fuel leakage from occurring. If you want to fix the issue caused due to the leaking of fuel from the carburetor's bowl, then you could try replacing the gasket on the underside of it. One or more of the carburetor gasket (s) may be missing or damaged.Unplug both of the wires. Plug the black or white one into the generator's ground battery terminal. Plug your light into the generator and start the motor. Take the red cable from your 12+ vault battery, and connect it with the red brush cable. Hold both against the voltage generator terminal for 3-5 seconds.Check the Fuel. One of the most common causes of starting problems with Honda generators—and other brands for that matter—is deteriorated fuel. The fuel you use in your generator can degrade over time, and that deterioration can cause the generator to have startup problems. Since generators are used only occasionally, fuel deterioration is ...If your generator has old gas in it, you may need to drain it out and replace it with fresh gas. #2: It's Low on Oil. Just like with gas, generators also need oil to function. Without oil, that motor will start to grind on itself and burn up. Most modern generators come with low oil sensors to tell you when there is not enough oil left.MSRP. $4499*. 7000 watt 120/240V inverter generator with CO-MINDER™. 4.6. (204) Perfect for home back up power, RVs, outdoor events, and more. Super quiet & fuel efficient. Electric start. Honda My Generator app + Bluetooth ® capability.Messages. 6. Mar 17, 2021. #1. I have a Honda gc160 small generator.. it won't start just spits flames out the exhaust.. but if I loosen the bolts on the OHV cover , it's starts up brilliantly. But soon as I tighten the bolts it cuts back out ,, wonder if anyone else had this issue ,, thanks.Dec 14, 2013 · That's the thing on the bottom of the carb with two wires. If it's not working it cuts off fuel internally in the carb. Take it off and turn the key and crank it over. It should retract the needle when cranking and when running. What it does is when the unit shuts off it cuts fuel so the engine won't diesel. Here are the most common reasons your Honda generator's engine won't start - and the parts & instructions to fix the problem yourself. Fix things more easily! En español. 1-800-269-2609 24/7. Your Account ... Chainsaw Parts Tiller Parts Leaf Blower Parts Wood Chipper Parts Hedge Trimmer Parts Generator Parts Log Splitter Parts Pole Pruner ...The plug gap should be between 0.028-0.031 inches (0.7-0.8 mm.) To reinstall, screw the plug in by hand to keep it from cross-threading. Tighten down the plug with the plug socket or wrench, tightening 1/8-1/4 of a turn once the plug is seated. If the plug is new, tighten it 1/2 turn to ensure the plug washer makes a tight seal.Solution. You’ll need to inspect the integrity of the pulley by removing the starter and checking any damage on its parts. If it is broken or cracked, you need to replace it with a new one in the following steps: Pull the pull cord completely out of the pulley. Insert a screwdriver in the pulley to lock it in place.Images: 2. Yamaha ef2000is Generator - Won't Start. I forgot, left a small amount of fuel in it for an extended time. Now it won't start. I removed the air filter and used quick engine start (sprayed at location in second photo) and it then starts briefly but it won't keep running. I removed the component in the first photo and nothing ...Lightweight and compact. Weighing only 29 pounds, the EU1000 is incredibly lightweight and portable. Fuel efficient - runs up to 6.8 hr on 0.6 gal. of fuel. Thanks to our exclusive Eco Throttle System, the EU1000i offers great fuel efficiency. It runs 3.0 to 6.8 hours on a single tank, depending on the load.Check The Battery/Fuses. If your battery is too low, your generator probably won't start. Make sure you have adequate voltage for your generator to start by measuring the voltage output of its battery with a multimeter. Consider obtaining a jump-start from another car or attempting a flash generator with an external battery if you don't ...Gotta love Hondas. But not this time. Would not start. Nada. Stored carb dry, tank empty. Gas is a tad old (Feb '21) but still works fine in saws etc. There seems to be gas sucked in, plug looked wet after repeated attempts. And starting fluid did not help, either through carb or directly in plug hole.Honda Generator E1500 Wont Run?How to Fix points problem'sPoints wasn't set right , in this one is why it wont run.how to trouble shoot problems and repair your honda eu 2000i generator.Store your gasoline in a clean, plastic, sealed container approved for fuel storage. Close the vent (if equipped) when not in use and store the container away from direct sunlight. If it takes more than 3 months to consume the fuel in the container, we suggest adding a fuel stabilizer to the fuel when you fill the container. Keep your engine's ...

Options. Greetings, There are a number of things that can cause a starter rope to get stuck. If the engine has sat for a good bit the first thing I would do if it's difficult to pull is remove the spark plug and ease the compression until I was able to get oil to start lubricating the cylinder again. This could be a case of the cylinder isn .... Tractor supply rooster

honda generator wont start

If you’re having difficulty starting your engine, wait at least 10 seconds between starting attempts to let the starter cool. If your engine has an electric starter, it probably has Honda’s Oil Alert system. It uses a float inside the crankcase that is wired to the ignition system. If the float is too low, the power to the spark plugs is ...The most common generator problems are: Generator won't start. Generator starts and then dies. Generator is leaking gas. Generator bogs down under load. Take caution when performing repairs. Always remove the spark plug wire and wait for the engine to cool. Follow all safety precautions found in the operator's manual. Honda generator won’t start. It can be extremely frustrating if your generator won’t start. But usually, this is only the case because you simply aren’t doing something right or you’re neglecting to pay attention to a necessary warning or notice that there may have been delivered at some point in time. Now the other thing you can do, get a plastic tote from a store, set the genset inside or cover it with the tote. Use a 30-40 max watt light bulb on a thermostat that turns on the lamp at anything less that 55* F. Just make sure you cut a small vent hole for the gas vapor to escape, an it should start as normal.A Honda generator may start and then die due to a plugged air filter, wrong choke setting, clogged fuel line, plugged fuel filter, dirty carburetor, bad gas cap, dirty spark plug, faulty ignition coil, low …One of the most common reasons a generator won’t start is because the gas is old. When fuel sits for a long period of time, it degrades. ... I ‘ve seen honda powered GX120/GX160 engine generators for ~$50 used which is only what $18 more then a new carb for that generator, there is lots of coleman powermates and those little honda …Here's what I've found from my experience. If your generator starts but won't keep running, here are two likely issues to check: make sure that it's not overloaded. check for fuel or air delivery obstructions. A clogged air filter, vapor lock, or dirty carburetor often cause this issue.Jan 19, 2022 · You need to know that if you just acquired a new Honda eu3000 generator, you will have to hook up the battery. It does come with a battery, but it is disconn... This is also true with automobile batteries. As a result, you may need to replace the battery. #3. Insufficient Fuel In The RV's Fuel Tank. If your RV's gasoline tank falls below a quarter tank, the generator will run out of fuel. As a result, if the RV fuel tank is too low, the generator will not start.The most common fuel issue with the Honda generator EU3000is is a clogged fuel filter . If the generator is not getting enough fuel, it may start and then stall. To fix this issue, clean or replace the fuel filter. Another fuel issue is a clogged carburetor. If the carburetor is clogged, the generator may not start or run poorly.A generator will only keep running if it can start. If a generator can't start, it's not producing power. Understanding the starting circuit is important because it's one of the easiest and most common problems you'll encounter when working on residential generators. The Generator Starts But won't Stay RunningOutdoor Gasoline and Electric Powered Equipment and Small Engines - Honda EM2200 Generator Won't Start - Hello everyone...Just purchased a used Honda EM2200 generator powered by a GE 200 engine. When I first tried to start it and opened the fuel supply to the carburetor, it was leaking heavily from the carburetor area.One of the most common reasons a generator won’t start is because the gas is old. When fuel sits for a long period of time, it degrades. ... I ‘ve seen honda powered GX120/GX160 engine generators for ~$50 used which is only what $18 more then a new carb for that generator, there is lots of coleman powermates and those little honda …A generator won’t start when it isn’t getting sufficient fuel, air, and spark. This may be due to a plugged air filter, wrong choke setting, faulty on/off switch, empty fuel tank, plugged fuel filter, clogged fuel line, dirty carburetor, bad spark plug, bad spark arrestor, low engine oil, or faulty fuel cap. Check the battery, starter ... Owner's Manual EBGC 1000001 - 1010807. Owner's Manual EBGC 1010808 - 1501210. Owner's Manual AG, AN type EBGC 1501211 - 1508382. Owner's Manual AG, AN types (mfg on or after 4/1/23) EBGC 1508383 - 9999999. Breather Heater Kit EBGC 1000001 - 9999999. Common replacement parts guide EBGC 1000001 - 9999999. Generator will not start Troubleshooting (check air filter on generator) Next on the list, inspecting the air filter on the generator. The air filter can be easily accessed by unscrewing the wing nut on top of the air filter box. Here is a break down of the air cleaner assembly, taken from the Honda Generator EG1400X, EG2200x owners manual.Generator sputtering happens quite often; it's even common than you might think. If it does occur in your generator, you don't have to be worried as much. At times, you will start the generator, run as usual, but it starts sputtering along the way. It might even start sputtering right after starting the engine and eventually dies.A bit of a pain, but was wort it. My Yamaha 2000 has to come inside to start when its cold inside! At least the Honda tries! When the weather is cold,approaching freezing and just below, my generator is hard to start. Well really it starts quickly but shuts down after a few seconds for a low oil warning. The oil is not low..

Popular Topics